RadiCS UX2 | RadiForce

Monitor Quality Control Software & Calibration Sensor

The RadiCS software provides extensive validations and automatic adjustment to ensure constant and consistent image reproduction on all RadiForce screens.


Category

Monitor quality management, including calibration as well as acceptance and consistency testing, in one programme.

The RadiCS UX2 software is simple, easy to use and can even perform consistency test measurements fully automatically.

More information

Contact EIZO RadiForce team

T. 01344 317480
E. ukhealthcarevisual@eizo.com

RadiCS UX2 provides total support for the maintenance and control of client monitors.

radics a3c 1

1. Optimal quality control of image reproduction systems in radiological applications


The RadiCS UX2 quality control tool is capable of end-to-end monitor quality management, starting with calibration and acceptance/consistency testing through to network-supported quality assurance management in conjunction with RadiNET Pro. With the measurement sensors in modern RadiForce screens for diagnostic reporting, RadiCS UX2 can even fully automate consistency testing. The software is simple, easy to use and can even perform consistency test measurements fully automatically. EIZO offers an integrated solution consisting of software and sensors, which makes quality control both efficient and user-friendly.

radics workspace 9ae transformed 1

2. RadiCS UX2 provides you with the following benefits:


  • Acceptance and consistency testing according to QS-RL, DIN, PAS1054, AAPM and many other standards
  • DICOM® calibration of the tone value characteristic curve
  • Fully-automatic consistency testing with monitors featuring brightness and illuminance sensors
  • Archiving of calibration and test protocols
  • Monitoring of the sensor inside the monitor to control brightness and the tone value characteristic curve
  • Calendar with reminder function for recurring checks of reference and test patterns

3. Simple user interface for intuitive operation


Graphics, icons and texts are arranged in such a way that the functions are intuitive and logical based on their appearance. An overview list also allows users to immediately check the status of the monitors. The intuitive user interface makes it easy to calibrate and validate monitors.

4. Precision calibration


Regular calibration of monitors is key to ensuring consistently high image reproduction quality. Deviations in tone value rendering, which result even during normal use, are reliably eliminated, for example, in accordance with DICOM or CIE.

precision calibration 6fb

5. Acceptance and consistency testing


The installation of diagnostic monitors is subject to acceptance testing. Regular consistency tests are also essential. The RadiCS UX2 software supports these operations by way of visual checks using test patterns in accordance with DIN and AAPM, as well as luminance, tone value and homogeneity measurements in accordance with DIN, AAPM, IEC and JIS. RadiCS assigns acceptance and consistency tests of body regions/methods from DIN 6868-157 to application classes to allow for unambiguous categorisation during the related testing.

RadiCS UX2 application classes

Overview of EIZO RadiCS application classes and recommendation of EIZO image reproduction devices in accordance with the body regions and methods from DIN 6868-157.

RadiCS UX2 application classes and monitors at a glance

6. Self-calibration and self-diagnosis


RadiCS UX2 can perform self-calibration as well as self-diagnosis on the basis of factory calibration data for each respective screen. Depending on the RadiForce monitor, RadiCS UX2 uses the integrated front sensor or built-in backlight sensor for calibration. Self-calibration is performed quickly without a separate measuring device. If unstable or altered brightness levels are detected, an error message is output by the self-diagnosis function indicating that the hue curve requires recalibration. Self-diagnosis can be configured so that it is performed automatically at regular scheduled intervals.

ifs 53e

7. Flexible scheduling via RadiCS UX2


The time for carrying out quality control tasks such as daily visual checks or semi-annual consistency tests can be customised according to the requirements at the respective workstation, for example, when the PC is switched on or immediately after a specific application has been launched.

flexible scheduling f7c

8. Optimised diagnostics workflow


To increase work efficiency, EIZO’s Work-and-Flow function offers various features in order to provide user-friendly workflows. This includes the Point-and-Focus functionality that makes it possible to quickly select and zoom in on relevant image areas using the mouse or keyboard. By adjusting the brightness and greyscale levels, surrounding areas are darkened and interesting image regions are highlighted.

More information about the Work-and-Flow functions
radics work and flow funktionen af1

9. Documentation


Measurement results from calibration operations, monitor validation checks and self-tests are archived for each monitor individually and are available for future reference with RadiCS UX2.

10. Asset management


Device and model names, the names of the medical institution or department, the description of the installation location as well as other information on each monitor, computer and graphics board can be documented and archived with RadiCS UX2.

11. Extended service life thanks to automatic shutdown function


Numerous functions offered by the EIZO RadiCS UX2 software are also compatible with non-RadiForce monitors. This means that monitors from other manufacturers can also be managed simply and easily.

12. Universal compatibility


The automatic Backlight Saver shutdown function for the backlight on EIZO RadiForce screens can be configured using RadiCS UX2. This extends the service life of the monitors. Similar to a screen saver, they turn off the backlight when the monitor is not in use.

13. The perfect addition


If you work with several monitors, we recommend using RadiNET Pro software that allows you to centrally manage the calibration of all monitors, including the data history. This saves you considerable time and ensures uniformly high image quality throughout the entire facility.

Learn more about RadiNET Pro software (optionally available)
radinet pro 9a0

Where to buyBack to Top

Specifications for RadiCS

User modesuser (no password) and administrator (password protected)
Functions in user modedaily check, documentation, optional consistency check and Work-and-Flow functions
Functions in administrator mode all user functions, master data maintenance, monitor configuration, edit test specifications, etc.
Work-and-Flow functions Point-and-Focus, Switch-and-Go, Hide-and-Seek
Supported luminance metersLX-Can, LX-Plus, CDmon, CA-210/CA310, MAVO-Spot 2 USB, RaySafe X2 Light, integrated sensors
Test methodsmanual input, external measuring devices with data link, internal monitoring sensors
Ambient light test manual, continuous and automatic during validation checks
FormatDIN 6868-157
Quality Assurance/Quality Control Directive
DIN V 6868-57
ONR 195240-20:2017
PAS 1054
IPEM Report 91
EUREF ‘European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis Fourth Edition’
AAPM On-Line Report No. 03
ACR-AAPM-SIIM ‘Practice Guideline for Determinants of Image Quality in Digital Mammography’
New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programme Primary Diagnostic Monitors
NYC Quality Assurance Guidelines for Primary Diagnostic Monitors
JESRA X-0093*B-2017
Quality Control Manual for Digital Mammography (Japan)
Luminance characteristic curves DICOM Part 14, GSDF, CIE, exponential (gamma), loglinear, linear, user-defined
Compatible operating systems Windows 11
Windows 10
Windows 8.1
Windows 7 / 7 SP1
Windows Server 2019 Standard
Windows Server 2016 Standard
Windows Server 2012 R2 Standard
macOS Catalina (10.15)
macOS Mojave (10.14)
Supported interfaces USB, RS232C, DDC
LanguagesGerman, English, French, Chinese, Japanese
Included in delivery RadiCS DVD-ROM (RadiCS, user’s manual), UX2 sensor

Downloads

+Brochures


+Data sheet

Additional information
Product Range

Product Category

Areas of Application

Click outside to hide the comparison bar